Iranian Classification Society Rules

< Previous | Contents | Next >

Section 5 General Requirements of Electrical Equipment


502. System voltage


1. Where the electric power of which voltage exceeds the value specified in 502. 1 of the Rules is intended to be used data of construction, installation, testing method, etc. for the electrical equip- ment and cables are to be submitted to the Society.


2. Electrical equipment of which system voltage exceeds 500 V is to comply with the requirements Pt 6, Ch 1, Sec 16 of Rules for the Classification of Steel Ships.